1. AIR CONDITIONING SYSTEM AND VENTILATION SYSTEMS
A. Air Conditioning:
Air handler zones operated by remote mounted compressors with SMX controls. Zones are:
FN10C-P/EHBO10C - Stbd. Guest Cabin and head- (1 zone) 10,000 BTU
FN10C-P/EHBO10C - Port Guest Cabin and head- (1 zone) 10,000 BTU
FN12C-P/EHBO12C - Master cabin and head- 12,000 BTU (2 zones) 24,000 BTU
FN24C-P/EHBO24C - Wheelhouse- 24,000 BTU (2 zones) 48,000 BTU
FN12C-P/EHBO12C - Galley - 12,000 BTU (1 zone) 12,000 BTU
FN24C-P/EHBO24C - Salon- 24,000 BTU 48,000 BTU
FN16C-P/EHBO16C - Engine room- 16,000 BTU 16,000 BTU
2. HEATING
A. Heating: Above standard air-conditioning is “reverse cycle” for heating. Also, each air handler is equipped with an inductive “heat strip” for use in cold water situations where the reverse cycle system is not efficient.
3. ENGINE ROOM VENTILATION SYSTEM
A. Two (2) Intake Blowers - Grainger #3C964 230VAC 50/60HZ rated at 2000 CFM (56.6 CMM) @ 0.0" SP @ 60 Hz. Two (2) louvered vents on aft deck wings with screened blower inlet.
B. One (1) Exhaust Blower - Grainger #5C198 230VAC 50/60HZ rated at 2000 CFM (56.6 CMM) @ 0.0" SP @ 60 Hz. One (1) vent on aft side exhaust stack with screened blower inlet.
C. Fire/Smoke Dampers – Ruskin CD36 Low Leakage Control Damper, 12"x12" (30.48 cm x 30.48 cm) Stainless Steel Rear Flanged equipped with a side mounted Honeywell H-2024 (24VDC) Fast-Acting, Two Position Actuator. One damper (1) each installed on the engine room side of each blower for easy access. Each damper will be normally open and will close on SEAFIRE actuation. For boats equipped with main engine dry exhaust, one (1) damper each installed on the inside of each main engine exhaust stack louvered vent opening - damper size to be compatible with stack opening.
D. Auto Blower Stop and Damper Closure on Engine Room SEAFIRE Actuation (See Fire Protection System)
Note: See Noise Control item F
4. LAZARETTE AND FORWARD MACHINERY COMPARTMENT
A. One (1) Exhaust Blower each compartment- Grainger # 5C516 , 120vac. 60hz - rated at 150 CFM
B. Auto Blower Stop on Sea Fire Actuation in the compartment
5. HEADS
A. One (1) Exhaust Blower each head (3 total) - Grainger # 5C516 , 120vac. 60hz - rated at 150 CFM. On/Off wall switch for blower start and stop.
B. One (1) Decorator Spring-Wound Mechanical Timer each head - Intermatic Model FD30M, 0-30 minutes, SPST, Grainger Stock No. 1XC26. Switches wired in blower circuit to stop fan at zero setting. PAE to supply timers.
6. STATEROOMS
A. One (1) Supply Blower for master, forward guest staterooms (3 total). Jabsco Model #36770-0115 120vac. 60hz - rated at 150 CFM (4.25 CMM). On/Off wall switch for blower start and stop.
B. Outside air supplied from a louvered intake and ducted to the stateroom. Exhaust air from each stateroom routed to berthing passageway.
C. Blower located to insure minimal noise in stateroom

Last updated: 07/18/08

 