Air Conditioning System: |
| |
|
Cruisair Tempered Water System (chilled water) 108,000 BTU/hr 230vac 60Hz |
| |
A. |
Modular Tempered Unit: Three (3) MTC36 |
| |
B. |
Control Panel: MPEDR2UC1 (TALC 2-Unit Panel, two (2) Pump Relays 230V 1 PH) |
| |
C. |
Air Handlers BP 230V: |
| |
|
One (1) Cruisair CBBL6C - Lower Mid Cabin |
| |
|
One (1) Cruisair CBBL12C - Forward Cabin/Laundry Room |
| |
|
One (1) Cruisair CBBL12C - Master Stateroom |
| |
|
Two (2) Cruisair CBBL18C - Galley/Salon |
| |
|
One (1) Cruisair CBBL12C/ One (1) Cruisair CBBL18C - Wheel House |
| |
|
One (1) Cruisair CBBL9C - Captain's Cabin |
| |
|
One (1) Cruisair CBSB24C Slimline - Engine Room |
| |
D. |
Circ Pump: CPOD120BX |
| |
E. |
Sea Water Pump: PS1500BX |
| |
F. |
Controllers: |
| |
|
Eight (8) SMXHT Digital controls |
| |
|
Eight (8) CXP10 Cable Interconnect |
| |
|
Eight (8) TSEP10 Cable Temp Sensing Element with RF-11 |
| |
G. |
Accessories: |
| |
|
EXT120 Expansion Tank-TW-Bladder |
| |
|
BFC27 Balancing Flow Control |
| |
|
1060915 Automatic Vent |
| |
|
1070200 Backflow Preventer Valve |
| |
|
1070201 Pressure Regulator Valve |
| |
|
|
| 2. |
|
Engine Room Ventilation System |
| |
A. |
Two (2) Intake Blowers - Grainger #3C964 230VAC 50/60HZ rated at 1,210 CFM @ 0.0" SP @ 60 Hz. Two (2) louvered vents on aft deck wings with screened blower inlet. |
| |
B. |
One (1) Exhaust Blower -Grainger #IXJY4 230VAC 50/60HZ rated at 1,210 CFM @ 0.0" SP @ 60 Hz. One (1) vent on aft side exhaust stack with screened blower inlet. |
| |
C. |
Fire/Smoke Dampers: Ruskin CD36 Low Leakage Control Damper, 12"x12" (30.5 cm x 30.5 cm) Stainless Steel Rear Flanged equipped with a side mounted Honeywell H-2024 (24VDC) Fast-Acting, Two Position Actuator. One damper (1) each installed on the engine room side of each blower for easy access. Each damper will be normally open and will close on Seafire actuation. For boats equipped with main engine dry exhaust, one (1) damper each installed on the inside of each main engine exhaust stack louvered vent opening - damper size to be compatible with stack opening. |
| |
D. |
Auto Blower Stop and Damper Closure on Engine Room Seafire Actuation (See Fire Protection System) |
| |
|
Note: See Noise Control item section B. 9 F |
| |
|
|
| 3. |
|
Lazarette and Forward Machinery Compartment |
| |
A. |
One (1) Exhaust Blower each compartment (3 Total) - Grainger # 5C517 , 120VAC. 60Hz - rated at 150 CFM |
| |
B |
Auto Blower Stop on Seafire Actuation in the compartment |
| |
C |
Forward bilge and machinery compartment blowers to be 24V continuous duty. |
| |
D |
Install stainless ladder from the lazarette to the cockpit level. On the cockpit level a vertical handrail on the BBQ console to allow a person to easily climb out of the lazarette. |
| |
|
|
| 4. |
|
Heads |
| |
A. |
One (1) Exhaust Blower each head (Five (5) total) - Grainger # 5C516, 120VAC. 60Hz - rated at 150 CFM. On/Off wall switch for blower start and stop. |
| |
B. |
10 minute timer for each exhaust fan |
| |
|
|
| 5. |
|
Staterooms |
| |
A. |
One (1) Supply Blower for master, forward guest staterooms (4 total). Grainger # 5C516 , 120vac. 60hz - rated at 150 CFM. On/Off wall switch for blower start and stop. |
| |
B. |
Outside air supplied from a louvered intake and ducted to the stateroom. Exhaust air from each stateroom routed to berthing passageway. |
| |
C. |
Blower located to insure minimal noise in stateroom |