1.
AIR CONDITIONING SYSTEM:
CRUISAIR Tempered Water System (chilled water) 12ton (3xMTC48DC) 208vac-230vac 3-phase 50/60hz per PAE design #86-00-AIRCON
A.
Modular Tempered Unit: FMTC3X4HDC Framed Chiller, 12tons, 3-stage, 230v50/60hz, 3ph.
B.
Control Panel: MPEDR3UDC1 TWLC3-Unit Panel , 2 Pump Relays, 230v -3ph.
C.
Air Handlers 237Btu/hr total 208vac 60HZ 3 - phase:
2 x ATB9C - Lower Mid Cabins and heads
1 x ATB6C - Lower Fwd. Cabin and head
2x ATB12C - Master Stateroom and head
2x ATB18C - Galley/Dining
2 x ATB18C - Salon and day head
2 x ATB12C - Wheel House
1 x ATB12C - Captains Cabin and Head
2x ATB12C- Sky Lounge
1 x ATB9C- Crew Cabin/Laundry area
1 x CBSBF24C - Engine room
D.
Circ Pump: CPOD180B3X
E.
Sea Water Pump: PS3000B3X
F.
Room Controllers:
11 SMXHTG, SMX LCD Key Pad/Display, Grey
11 PLTX-HVSTAT, SMXII PWR LGC BX for TW/New HV Board
5 CXP30 Cable Interconnect 30' SMXir
6 CXP10 Cable Interconnect 10'-SMXir
11 TSEP5 Cable Temp Sensing Element with RJ-11 5'-3"
G.
Accessories:
EXT240 Expansion Tank-TW-Bladder
BFC66 Balancing Flow Control
1060915 Automatic Vent
1070200 Backflow Preventer Valve
1070201 Pressure Regulator Valve
DSV2/240 Vent Dual Spiro 2in FPT/240Btu/hr Max
1010020 Strainer
 
2.
ENGINE ROOM VENTILATION SYSTEM
A.
Two (2) Intake Fans - Multifan model #4E50-240V 60HZ 20" dia. rated at 4638 CFM @ 0.0" SP. Two (2) louvered vents on P&S side deck at fwd end of engine room with screened blower inlet. Each intake fan will pull through a Delta T moisture eliminator located at the deck side. PAE to supply the moisture eliminators.
B.
Two (2) Exhaust Fans - Multifan model #4E50-240V 60HZ 20" dia. rated at 4638 CFM @ 0.0" SP. Two (2) louvered vents on P&S side deck at fwd end of engine room with screened blower inlet.
C.
Fire/Smoke Dampers – Ruskin Low Leakage Control Damper, 18"x18" Stainless Steel Rear Flanged equipped with a side mounted Honeywell H-2024 (24VDC) Fast-Acting, Two Position Actuator. One damper (1) each installed on the engine room side of each blower for easy access. Each damper will be normally open and will close on SEAFIRE actuation. For boats equipped with main engine dry exhaust, one (1) damper each installed on the inside of each main engine exhaust stack louvered vent opening - damper size to be compatible with stack opening.
D.
(2) intake fans and (2) exhaust fans have adjustable speed controls Grainger model #3C955 to adjust engine room air flow.
Auto Blower Stop and Damper Closure on Engine Room SEAFIRE Actuation (See Fire Protection System)
Note: See Noise Control item F
 
3.
LAZARETTE
A.
One (1) Exhaust Blower - Multifan model #4E25-240V 60HZ 10" dia. Rated at 882 CFM @ 0.0" SP. Intake air will be passive from holes in the cockpit lockers.
B.
One (1) General Service Temperature Switch - bulb and capillary type, range 1-150 degrees F, SPDT rated at 15 amps at 125/480VAC. McMaster-Carr# 47525K62. Switches wired in blower circuit with contacts closing on rising temperature.
C.
Auto Blower Stop on SEAFIRE Actuation in the compartment
 
4.
HEADS
A.
One (1) Exhaust Blower each head - Jabsco Model #36770-0115 rated at 250 CFM 120vac
B.
One (1) Imtra on/off switch with indicator light for each head.
C.
Ducting is to be 4" ID.
 
5.
STATEROOMS
A.
One (1) Supply Blower for master, and lower staterooms (6 total). McMaster-Carr model #19135K85 rated at 122 CFM 120vac. On/Off wall switch for blower start and stop.
B.
Blower located to insure minimal noise in stateroom
C.
Ducting is to be 4" ID.
D.
Cabin intake air is to come from a louvered intake from outside the boat and ducted to the stateroom.