Water tank: |
Number and capacity: Three (3) baffled tanks totaling 250 gallons (946.4 Liters) |
FRP construction with Vinylester resin and FDA approved gelcoat, per plan |
Inspection plates: appropriately positioned for access |
Each tank air tested: 4 lbs (1.81 kg) per sq. inch |
Wema water tank gauges |
System built per PAE design |
Water tank laid up with FDA approved gel coat |
|
Fuel tank: |
Number and capacity: Three (3) main tanks totaling 800 gallons (3028.3 Liters) with one centerline aluminum "Supply Reservoir" at 12 gallons (45 Liters) which will gravity feed from the two (2) main wing tanks and one (1) aft tank |
FRP construction with Vinylester resin per plan |
Inspection plates appropriately positioned for interior access by average size man. Each internal baffle with a removable panel to allow access to entire interior of both fuel tanks |
Fuel system to include an aluminum supply reservoir, which feeds by gravity from three (3) fuel tanks. Top part of supply reservoir to hold approximately two (2) gallons (7.6 Liters) and fitted with a sight gauge with a one (1) gallon (3.8 Liters) range and 10th gallon (.4 Liter) marks for fuel consumption checks (supply lines are turned off and fuel is consumed from reservoir). Bottom part of reservoir to be approximately ten (10) gallons (37.8 Liters) fitted with a drain off at the bottom of the reservoir for water purging and with a water sensor - illuminating a light in wheelhouse if excessive water is present. Reservoir fitted with three (3) draw spigots for main, generator, and spare - mounted at lower level of reservoir but above water sensing probe. All returns from main, and generator plumbed into reservoir |
Sight gauges on all three tanks |
Each tank to be air tested to 4 lbs (1.81 kg) per sq. inch |
Provide baffles on 24" (61 cm) centers |
A transfer manifold and Walbro (FRB 16-2) fuel pump with timer switch and Racor 900MA fuel filter which can transfer fuel from one tank to another and scrub fuel while transferring. Transfer is also used to fill top part of supply reservoir for consumption testing when main fuel tank level drops below the level of the testing part of the reservoir |
System to be built per PAE design |
|
Fuel pipe and hose: |
Supply lines from tanks to supply reservoir are 3/4" (1.9 cm) I.D. with Aeroquip brand fuel hose and swaged fittings |
Fuel line from supply reservoir to main engine filter is 1/2" (1.27 cm) I.D. with Aeroquip brand fuel hose and swaged fittings |
Fuel lines from supply reservoir to optional generator to be 1/2" (1.27 cm) I.D. with Aeroquip brand fuel hose and swaged fittings |
Vent lines to be USCG fuel certified, reinforced hose 3/4" (1.9 cm) I.D. |
Fuel fill hose to be Trident #A2 type, 2" (5.08 cm) I.D. US Coast Guard approved |
|
Water hoses: |
Hot water: 3/4" (1.9 cm) supply 1/2" (1.27 cm) diameter distribution. Shurflo brand "Shurpex semi rigid tubing or equivalent with all Shurpex red fittings per system drawing |
Cold water: 3/4" (1.9 cm) supply 1/2" (1.27 cm) diameter distribution Shurflo brand "Shurpex semi rigid tubing or equivalent with all Shurpex blue fittings per system drawing |
Sea water hoses: Trident reinforced rubber certified for marine use and provided with double stainless steel clamps below the water line |
|
Water heater: Seaward # S1150 or Attwood 11 gallon (41.6 Liters) for 220 volt and heat exchanger operation |
|
Thru Hulls: bronze body, stainless steel balls and Teflon seats |
Grounding wire: #6 gauge green wire run to 1/8" x 3/4" (3.2 mm x 19 mm) copper strap that runs down both sides of hull |
Each thru hull to have a clearly visible tag indicating its function |
|
Fresh water pressure pump: One (1) Jabsco Sensor Max VSD #31765-0094 |
|
Plumbing fixtures: |
Head sinks: HCG #3371 like N64 |
Galley sink: Large double stainless steel sink |
Head faucets: Grohe model #33170 000 chrome |
Galley faucets: Grohe model #33939 1B0 chrome with black |
Shower fixtures: Grohe chrome #28.175 handle |
| #28.631 soap tray |
| #28.620 24" (61cm) shower bar |
| #28.151 non-metallic hose |
| #34.436 mixer |
|
Bilge pumps: per PAE design |
Electric: Par #34600-10 24 volt electric diaphragm pump with Ultra Junior auto float switch #UPS-02 24 volt |
Manual: Edson model #638AL operable from main salon |
High water bilge pump Rule 3700 gallons (14,006 Liters) per hour #16A - mounted in bilge above normal bilge water height including Ultra Sr. pump switch #UPS-01 24 volt and Ultra bilge alarm #A-201-S Surface mount panel |
|
Toilets: |
Tecma "Silence Plus Short" fresh water flush only with 3/4" (1.9 cm) fresh water supply |
Head fitted with a Par #45510-1000 Y valve allowing sewage to be pumped overboard or into holding tank |
Holding tank: FRP |
Holding tank pump: Sealand T-24, 24 volt plus Whale/Henderson #BP0527 hand operated diaphragm pumps to be installed in-line with each other per PAE design |
Holding tank fitted with a deck pump out |
Sealand Tank Watch 4 monitoring system |
All holding tank and toilet hoses to be Trident #102 |
|
All hoses throughout boat to be Trident brand with CE approval - where practical |
|
LPG system |
Two (2) Worthington #D200145WCI 20 lb. (9.07 kg) LPG bottles in port side transom locker |
Xantex control panel and detection system S-2A and MS-2 sniffer / 24-12 volt converter (CVN 24-12) |
Two-stage regulator #12301411 |
Trident 'Pig Tail' hoses x two (2) #1014140120 |
All necessary pipe fittings and adapters |
|
Showers to drain with 24 volt sump pumps: |
Whale "Gulper 220" #BP1554 24 volt DC 2.5 amp x two (2) |
30 minute timer switch x two (2) |