Air Conditioning & Ventilation System

Air Conditioning System 50/60 Hz

Cruisair Tempered Water System (chilled water) 108,000 BTU/hr 230 volt AC 60 Hz

Modular Tempered Unit: Three (3) MTC36

Control Panel: MPEDR2UC1 (TALC 2-Unit Panel, 2 Pump Relays 230 volt 1 PH)

Air Handlers BP 230 volt

Two (2) x Cruisair CBBL9C - Lower Mid Cabin/Laundry Room

Two (2) x Cruisair CBBL12C - Master Stateroom

Two (2) x Cruisair CBBL18C - Salon

One (1) x Cruisair CBBL12C - Galley

One (1) x Cruisair CBBL12C / One (1) Cruisair CBBL18C - Wheel House

One (1) x Crusiair CBBL18C - Crew

One (1) x Cruisair CBSB24C Slimline - Engine room

Circ Pump: 225500178

Sea Water Pump: PS1500BX

Controllers

Eight (8) SMXHT Digital controls

Eight (8) CXP10 Cable Interconnect

Eight (8) TSEP10 Cable Temp Sensing Element with RF-11

Accessories

EXT120 Expansion Tank-TW-Bladder

BFC27 Balancing Flow Control

1060915 Automatic Vent

1070200 Backflow Preventer Valve

1070201 Pressure Regulator Valve


Engine Room Ventilation System

Two (2) Intake Blowers - Grainger #3C964 230 volt AC 50/60 Hz rated at 1,210 CFM @ 0.0" SP @ 60 Hz. Two (2) louvered vents on aft deck wings with screened blower inlet

One (1) Exhaust Blower -Grainger #IXJY4 230 volt AC 50/60 Hz rated at 1,210 CFM @ 0.0" SP @ 60 Hz.

Fire/Smoke Dampers: Ruskin CD36 Low Leakage Control Damper, 12"x12" (30.5 cm x 30.5 cm) Stainless Steel Rear Flanged equipped with a side mounted Honeywell H-2024 (24 volt DC) Fast-Acting, Two Position Actuator. One (1) damper each installed on the engine room side of each blower for easy access. Each damper will be normally open and will close on Seafire actuation.

Auto Blower Stop and Damper Closure on Engine Room Seafire Actuation (See Fire Protection System)

Note: See Noise Control Item Section B.9.f


Lazarette and Forward Machinery Compartment

One (1) Exhaust Blower each compartment (3 Total) - Grainger # 5C517 , 120 volt AC. 60 Hz - rated at 150 CFM

Auto Blower Stop on Seafire Actuation in the compartment


Heads

One (1) Exhaust Blower each head (5 total) - Grainger # 5C516 , 120 volt AC. 60 Hz - rated at 150 CFM. On/Off wall switch for blower start and stop

10 minute timer for each exhaust fan


Staterooms

One (1) Supply Blower for master, 2 guest staterooms and crew (4 total). Grainger # 5C516 , 120 volt AC. 60 Hz - rated at 150 CFM. On/Off wall switch for blower start and stop

Outside air supplied from a louvered intake and ducted to the stateroom. Exhaust air from each stateroom routed to berthing passageway

Blower located to insure minimal noise in stateroom


*Specifications subject to change without notice and at the discretion of designers and builders.
**Dimensions are subject to change with Buyer’s selected options and personal effects which may add to displacement and increase both draft and waterline length

Last updated: 1/20/10

 

 