Air Conditioning System 50/60 Hz |
Cruisair Tempered Water System (chilled water) 108,000 BTU/hr 230 volt AC 60 Hz |
Modular Tempered Unit: Three (3) MTC36 |
Control Panel: MPEDR2UC1 (TALC 2-Unit Panel, 2 Pump Relays 230 volt 1 PH) |
Air Handlers BP 230 volt |
Two (2) x Cruisair CBBL9C - Lower Mid Cabin/Laundry Room |
Two (2) x Cruisair CBBL12C - Master Stateroom |
Two (2) x Cruisair CBBL18C - Salon |
One (1) x Cruisair CBBL12C - Galley |
One (1) x Cruisair CBBL12C / One (1) Cruisair CBBL18C - Wheel House |
One (1) x Crusiair CBBL18C - Crew |
One (1) x Cruisair CBSB24C Slimline - Engine room |
Circ Pump: 225500178 |
Sea Water Pump: PS1500BX |
Controllers |
Eight (8) SMXHT Digital controls |
Eight (8) CXP10 Cable Interconnect |
Eight (8) TSEP10 Cable Temp Sensing Element with RF-11 |
Accessories |
EXT120 Expansion Tank-TW-Bladder |
BFC27 Balancing Flow Control |
1060915 Automatic Vent |
1070200 Backflow Preventer Valve |
1070201 Pressure Regulator Valve |
|
Engine Room Ventilation System |
Two (2) Intake Blowers - Grainger #3C964 230 volt AC 50/60 Hz rated at 1,210 CFM @ 0.0" SP @ 60 Hz. Two (2) louvered vents on aft deck wings with screened blower inlet |
One (1) Exhaust Blower -Grainger #IXJY4 230 volt AC 50/60 Hz rated at 1,210 CFM @ 0.0" SP @ 60 Hz. |
Fire/Smoke Dampers: Ruskin CD36 Low Leakage Control Damper, 12"x12" (30.5 cm x 30.5 cm) Stainless Steel Rear Flanged equipped with a side mounted Honeywell H-2024 (24 volt DC) Fast-Acting, Two Position Actuator. One (1) damper each installed on the engine room side of each blower for easy access. Each damper will be normally open and will close on Seafire actuation. |
Auto Blower Stop and Damper Closure on Engine Room Seafire Actuation (See Fire Protection System) |
Note: See Noise Control Item Section B.9.f |
|
Lazarette and Forward Machinery Compartment |
One (1) Exhaust Blower each compartment (3 Total) - Grainger # 5C517 , 120 volt AC. 60 Hz - rated at 150 CFM |
Auto Blower Stop on Seafire Actuation in the compartment |
|
Heads |
One (1) Exhaust Blower each head (5 total) - Grainger # 5C516 , 120 volt AC. 60 Hz - rated at 150 CFM. On/Off wall switch for blower start and stop |
10 minute timer for each exhaust fan |
|
Staterooms |
One (1) Supply Blower for master, 2 guest staterooms and crew (4 total). Grainger # 5C516 , 120 volt AC. 60 Hz - rated at 150 CFM. On/Off wall switch for blower start and stop |
Outside air supplied from a louvered intake and ducted to the stateroom. Exhaust air from each stateroom routed to berthing passageway |
Blower located to insure minimal noise in stateroom |